Introduction:
Sodium dodecylsulfate-polyacrylamide gel electrophoresis (SDS-PAGE) is a widely used technique for the separation and estimation of the molecular weight of individual proteins
Accuracy of molecular weight determination & characterization is limited by protein low recovery. Recently MALDI-TOF-MS has found widespread use for the determination of molecular mass of intact proteins isolated from gels. Isolation of proteins from gels with the newly developed GeBAflex-tube electro-elution system delivers over 80% recovery yields. Combination of SDS-PAGE, GeBAflex-tube electro-elution system, and MS buffer removing SDS (included in kit), delivers MALDI-TOF-MS, greater accuracy determination of protein molecular. Now we can analyze low & difficult protein, such as integral membrane proteins (hydrophobic) or high molecular masses protein.
The unique method provides a powerful means for characterizing endogenous proteins of wide molecular weight range separated by SDS-PAGE. The combinations of the three methods provide significantly improve protein yield and SDS free samples. The end result is a MALDI-MS analysis with greater sensitivity. GeBAflex-tube tool provide high protein yield recovery, MS buffer contained in GeBAflex-tube kit clean SDS thoroughly.
 
PRODUCT CATALOG REFERENCE
Purity: No contamination with Protease, RNase, DNase and PCR product free.
Membrane: ultra-clean, sulfur and heavy metal free and EDTA treated.
Single use unit, no need for cleaning and autoclave. Single step process.
A Maxi GeBAflex-tube inside Maxi-supporting tray.

High throughput electro elution with GeBAflex-tube using standard electrophorese unit.
Picture show 24 Midi GeBAflex-tube electro eluting, typical 50kDa/ 80mïn.

Picture show 4 Midi GeBAflex-tube electro eluting, typical 50kDa/ 80mïn.

Mini GeBaflex-tube Vol. 10-250µl, Max. gel slice size for electro elution: 0.4x1cm
Mini support plate: High x width between electrodes = 45 x 75mm, minimum depth 14mm
|
Product
|
Unit
|
MWCO
|
Catalog
|
|
GeBAflex-tube
|
10
|
6-8 kDa
|
TO70-6-10
|
|
GeBAflex-tube
|
30
|
6-8 kDa
|
TO70-6-30
|
|
GeBAflex-tube
|
10
|
12-14 kDa
|
TO70-12-10
|
|
GeBAflex-tube
|
30
|
12-14 kDa
|
TO70-12-30
|
Midi GeBaflex-tube Vol. 50-800µl, Max. gel slice size for electro elution: 0.5x1cm Midi support plate for 4 midi GeBAflex-tube : High x width between electrodes = 67 x 111mm, minimum depth 24mm
|
Product
|
Unit
|
MWCO
|
Catalog
|
|
GeBAflex-tube
|
10
|
3.5 kDa
|
TO10
|
|
GeBAflex-tube
|
15
|
3.5 kDa
|
TO11
|
|
GeBAflex-tube
|
20
|
3.5 kDa
|
TO14
|
|
GeBAflex-tube
|
30
|
3.5 kDa
|
TO12
|
|
GeBAflex-tube
|
10
|
6-8 kDa
|
TO20
|
|
GeBAflex-tube
|
15
|
6-8 kDa
|
TO21
|
|
GeBAflex-tube
|
20
|
6-8 kDa
|
TO24
|
|
GeBAflex-tube
|
30
|
6-8 kDa
|
TO22
|
Maxi GeBaflex-tube Vol 100-3000µl, Max. gel slice size for electro elution: 1x2cm
Maxi support plate for 3 maxiGeBAflex-tube: High x Width between electrodes = 92 x 113 mm, minimum depth 28mm
|
Product
|
Unit
|
MWCO
|
Catalog
|
|
GeBAflex-tube
|
5
|
3.5 kDa
|
TO30
|
|
GeBAflex-tube
|
15
|
3.5 kDa
|
TO35
|
|
GeBAflex-tube
|
5
|
6-8 kDa
|
TO40
|
|
GeBAflex-tube
|
15
|
6-8 kDa
|
TO45
|
|
GeBAflex-tube
|
5
|
12-14kDa
|
TO50
|
|
GeBAflex-tube
|
15
|
12-14kDa
|
TO55
|
|